The grate is representative of the entire design line.
Slotted grating
Length: 50, 100 cm
Load class: A15
Matching channel body
Load class:
A15, B125
Load class:
A15, B125, C250
Load class:
A15, B125, C250
Load class:
A15, B125
ANRIN SELF structural elements made of resin concrete
The classic from ANRIN is a reliable helper. Whether constant rain, downpour or thaw: the ANRIN SELF-100 drainage system made of indestructible resin concrete ensures that you won’t ever have to walk through puddles on your way through the courtyard to the garage or to your home. Various gratings made of different materials are available to create an optically appealing individual design for the cover. A complete kit for the DIY segment is comprised of 1 m channel elements, 50 cm adapter elements, the matching faces as channel end caps and a 50 cm sump unit with dirt trap bucket and connection opening. As a particularly helpful tool for connection to the pipeline, the developers at ANRIN have come up with a channel version with installed pipe sockets. These make it easy to create precise connections in just a few simple steps.
SELF-100 Smart channel product specifications | |
---|---|
Material | polymer concrete |
Length | 50 / 100 cm |
Width | 12.2 cm |
Height | 9.6 - 10.3 cm |
Weight | 4.2 - 12.4 kg |
Nominal width | 100 |
Joint formation | UNILINK® joint |
Clasp | Clip locking |
Load capacity | Slotted grating HEELGUARD, galvanised steel, stainless steel, cl. A15; Mesh grating, galvanised steel, cl. B125; Longitudinal profile grating, stainless steel, cl. A15; Slotted grating OvalGrip, ductile-iron, cl. B125; Slotted grating OvalGrip, polyamide, cl. B125 |
Grating | Longitudinal profile grating, Mesh grating, Polyamid grating OvalGrip, Slotted grating HEELGUARD, Slotted grating OvalGrip Design |
ANRIN Snap-in fastening
Decades of experience and detailed product development in the areas of assembly, maintenance and cleaning of drainage systems have produced impressive solutions for permanent fastening technologies.
ANRIN Snap-in fastenings are optimised for the specific load classes and unite reliability and high quality with functional design.
Accessories for SELF-100 Smart
End cap PP made of Polypropylen
black
SELF-100 Smart
End cap PP made of Polypropylene
grey
SELF-100 Smart
End cap PP made of Polypropylene
black
SELF-100 Smart
End cap PP made of Polypropylene
grey with pipe connection
SELF-100 Smart
SELF 100 Smart leaf mesh
SELF-100 Smart
Sump unit
SELF-100 Smart
Venturi insert
pre-assembled
SELF-100 Smart
SELF installation instructions
With ANRIN drainage systems, accumulating rainwater should be drained safely and quickly. Moreover, the structural elements have the task of accommodating dynamic loads arising from traffic-related demands and dispersing them to the area of the foundation.
Amongst others, the following technical rules and regulations in their respective valid versions must be observed for the selection, design and installation of ANRIN drainage systems.
The following installation guidelines are schematic representations. These are provided as examples and are non-binding. The information provided here is based on our long-term experience in excavation and road construction as well as the state-of-the-art technology. Despite this, designers and planners are always obligated to check the products and the installation instructions for their appropriateness. The example details are simplified recommendations for execution.
Constructions are to be re-created on a project-specific basis.
1.
Excavate trench. Fill in and pre-compact base course. Apply concrete pad, 3 parts sand + 1 part cement + 1 part water, to base course.
2.
Connect pipe connections to the pipeline.
3.
Place channel elements and sump unit on the concrete pad. Align components so that they are level.
4.
Position end caps.
5.
Complete the series and ensure the level alignment of the components.
6.
Backfill the concrete pad.
7.
Lay the paving.
8.
The surface should be 2 to 5 mm higher than the cover grating.
Instructions and Regulations
Guidelines and regulations
The current guidelines and regulations of the state-of-the-art technology must be observed for the installation.
For example, these are:
DIN EN 1433 „Drainage channels for vehicular and pedestrian areas“
DIN 19580 „Drainage channels for vehicular and pedestrian areas“
RStO „Guidelines for the standardisation of the superstructure of vehicular areas“
DIN EN 206-1 „Concrete. Specification, performance, production and conformity“
DIN EN 1045-2 „Concrete, reinforced and prestressed concrete structures. Part 2: Concrete – Specification, properties,
production and conformity; Application rules for DIN EN 206-1“
SELF PP Plastic channel product specifications | |
---|---|
Material | plastic polypropylene, polyamide (black) |
Length | 100 cm |
Width | 12.1. 13.1 cm |
Height | 6.3. 8.4. 10.0. 16.0. cm |
Weight | 1.6 - 1.8. 2.2. 2.7. 3.9. 7.3 kg |
Nominal width | 100 |
Joint formation | overlapping joint with latching system |
Clasp | Snap-in fastening, TwistLock fastening |
Load capacity | A15 (test force 15 kN) to C250 (test force 250 kN) |
Grating | Plastic grating, Plastic grating, Slotted grating, Slotted grating OvalGrip Design |
ANRIN UNILINK®-Joint
The optimised UNILINK® joint system eliminates the traditional differentiation between the beginning and end of the channel. Elements of an equal installation height can be joined in any arbitrary direction. The symmetrically divided half-joints enable the optional sealing of the splicing. Vertically aligned grooves and tongues support an efficient installation: In the process, the installation alignment can be chosen arbitrarily!
The flexibility in the design and installation phases enters a new dimension with the UNILINK® joint!
ANRIN Screw fastening
Decades of experience and detailed product development in the areas of assembly, maintenance and cleaning of drainage systems have produced impressive solutions for permanent fastening technologies.
ANRIN fastenings are optimised for the specific load classes and unite reliability and high quality with functional design.
ANRIN Snap-in fastening
Decades of experience and detailed product development in the areas of assembly, maintenance and cleaning of drainage systems have produced impressive solutions for permanent fastening technologies.
ANRIN Snap-in fastenings are optimised for the specific load classes and unite reliability and high quality with functional design.
Accessorie for SELF PP 080
Adapter
with screws for linking with DN 100 pipe connections
SELF PP
End wall pair
080 for channel tongue and groove
SELF PP
End wall pair
SELF PP
Sump unit
SELF PP
SELF installation instructions
With ANRIN drainage systems, accumulating rainwater should be drained safely and quickly. Moreover, the structural elements have the task of accommodating dynamic loads arising from traffic-related demands and dispersing them to the area of the foundation.
Amongst others, the following technical rules and regulations in their respective valid versions must be observed for the selection, design and installation of ANRIN drainage systems.
The following installation guidelines are schematic representations. These are provided as examples and are non-binding. The information provided here is based on our long-term experience in excavation and road construction as well as the state-of-the-art technology. Despite this, designers and planners are always obligated to check the products and the installation instructions for their appropriateness. The example details are simplified recommendations for execution.
Constructions are to be re-created on a project-specific basis.
1.
Excavate trench. Fill in and pre-compact base course. Apply concrete pad, 3 parts sand + 1 part cement + 1 part water, to base course.
2.
Connect pipe connections to the pipeline.
3.
Place channel elements and sump unit on the concrete pad. Align components so that they are level.
4.
Position end caps.
5.
Complete the series and ensure the level alignment of the components.
6.
Backfill the concrete pad.
7.
Lay the paving.
8.
The surface should be 2 to 5 mm higher than the cover grating.
Instructions and Regulations
Guidelines and regulations
The current guidelines and regulations of the state-of-the-art technology must be observed for the installation.
For example, these are:
DIN EN 1433 „Drainage channels for vehicular and pedestrian areas“
DIN 19580 „Drainage channels for vehicular and pedestrian areas“
RStO „Guidelines for the standardisation of the superstructure of vehicular areas“
DIN EN 206-1 „Concrete. Specification, performance, production and conformity“
DIN EN 1045-2 „Concrete, reinforced and prestressed concrete structures. Part 2: Concrete – Specification, properties,
production and conformity; Application rules for DIN EN 206-1“
SELF GL-100 channel product specifications | |
---|---|
Material | polymer concrete |
Length | 50 / 100 cm |
Width | 13 cm |
Height | 8 - 25 cm |
Weight | 10 - 18 kg |
Nominal width | 100 |
Joint formation | Tongue and groove |
Clasp | TwistLock fastening |
Load capacity | galvanised slotted grating cl. A15, mesh grating cl. B125, cast grating cl. C250 |
ANRIN TwistLock fastening
Decades of experience and thorough product development in the fields of installation, maintenance and cleaning of drainage systems have produced convincing solutions for durable closure technologies.
ANRIN grate closures are optimized for the respective load classes and combine safety and brand quality with functional design.
The TwistLock closure finds its application in grate designs for channels of nominal width 100 mm.
Advantages:
· Put in place – one rotation – fixed
· Assembly without special tools
· No rattling, no loosening
· No disruptive bars in the channel interior area
· Maintenance-friendly
· Resistant to corrosion
Accessorie for SELF GL-100
Channel body
SELF GL-100
Channel body
100 cm
with pipe socket
SELF GL-100
End cap
SELF GL-100
End cap
with DA / OD 110 pipe socket
SELF GL-100
Sump unit
SELF GL-100
SELF installation instructions
With ANRIN drainage systems, accumulating rainwater should be drained safely and quickly. Moreover, the structural elements have the task of accommodating dynamic loads arising from traffic-related demands and dispersing them to the area of the foundation.
Amongst others, the following technical rules and regulations in their respective valid versions must be observed for the selection, design and installation of ANRIN drainage systems.
The following installation guidelines are schematic representations. These are provided as examples and are non-binding. The information provided here is based on our long-term experience in excavation and road construction as well as the state-of-the-art technology. Despite this, designers and planners are always obligated to check the products and the installation instructions for their appropriateness. The example details are simplified recommendations for execution.
Constructions are to be re-created on a project-specific basis.
1.
Excavate trench. Fill in and pre-compact base course. Apply concrete pad, 3 parts sand + 1 part cement + 1 part water, to base course.
2.
Connect pipe connections to the pipeline.
3.
Place channel elements and sump unit on the concrete pad. Align components so that they are level.
4.
Position end caps.
5.
Complete the series and ensure the level alignment of the components.
6.
Backfill the concrete pad.
7.
Lay the paving.
8.
The surface should be 2 to 5 mm higher than the cover grating.
Instructions and Regulations
Guidelines and regulations
The current guidelines and regulations of the state-of-the-art technology must be observed for the installation.
For example, these are:
DIN EN 1433 „Drainage channels for vehicular and pedestrian areas“
DIN 19580 „Drainage channels for vehicular and pedestrian areas“
RStO „Guidelines for the standardisation of the superstructure of vehicular areas“
DIN EN 206-1 „Concrete. Specification, performance, production and conformity“
DIN EN 1045-2 „Concrete, reinforced and prestressed concrete structures. Part 2: Concrete – Specification, properties,
production and conformity; Application rules for DIN EN 206-1“
SELF Mini channel product specifications | |
---|---|
Material | polymer concrete |
Length | 100 cm |
Width | 12 cm |
Height | 6 cm |
Weight | 6.3 kg |
Nominal width | 100 |
Joint formation | UNILINK®- Joint |
Clasp | Snap-in fastening |
Load capacity | Galvanised slotted grating cl. A15, cast grating cl. B125, plastic grating cl. B125 |
ANRIN UNILINK®-Joint
The optimised UNILINK® joint system eliminates the traditional differentiation between the beginning and end of the channel. Elements of an equal installation height can be joined in any arbitrary direction. The symmetrically divided half-joints enable the optional sealing of the splicing. Vertically aligned grooves and tongues support an efficient installation: In the process, the installation alignment can be chosen arbitrarily!
The flexibility in the design and installation phases enters a new dimension with the UNILINK® joint!
ANRIN Snap-in fastening
Decades of experience and detailed product development in the areas of assembly, maintenance and cleaning of drainage systems have produced impressive solutions for permanent fastening technologies.
ANRIN Snap-in fastenings are optimised for the specific load classes and unite reliability and high quality with functional design.
Accessorie for SELF Mini
End cap PP made of Polypropylene
grey
SELF Mini
End cap PP made of Polypropylene
black
SELF Mini
Das ausgewählte Rost ist nicht in der Belastungsklasse verfügbar. Möchten Sie zur Rost-Übersicht für die gewünschte Belastungsklasse?
Das ausgewählte Rost ist nicht in der Nennweite verfügbar. Möchten Sie zur Rost-Übersicht für die gewünschte Nennweite?
Das ausgewählte Rost ist nicht mit diesem Material verfügbar. Möchten Sie zur Rost-Übersicht mit dem gewünschten Material?
Das ausgewählte Rost ist nicht mit dem gewünschten Filter verfügbar. Möchten Sie zur Rost-Übersicht?