Plastic grate

Material: polyamide
Length: 50 cm
Load class: A15

Matching channel body

SELF LC-150, 090, 125, 200 Plastic channel
Load class:
A15, B125, C250
Image Plastic channel
Image Plastic grate

The grate is representative of the entire design line.

ANRIN plastic drainage channels

The material is particularly resistant to all chemical and organic substances and is “self-cleaning”. Shockproof, unbreakable and with exceptional performance – even in cases of high temperature fluctuations (from -40 °C to 100 °C). The material is manufactured from PE-HD. This is used to drain rain water and liquids in industry. Its ability to be combined with different cover gratings means that it can also be used in pedestrian zones, in public spaces and in residential construction.

SELF LC-150, 090, 125, 200 Plastic channel product specifications
Material plastic polypropylene, polyamide (black)
Length 100 cm
Width 20.0 cm
Height 9.0. 12.5. 20.0 cm
Weight 4.6 - 19.5 kg kg
Nominal width 150
Joint formation

overlapping joint with latching system

Clasp Locking bridge
Load capacity A15 (test force 15 kN) to C250 (test force 250 kN)
Grating Mesh grating

Channel dimensions for plastic channel LC-150

Image Gutter size for SELF LC-150, 090, 125, 200 Plastic channel

SELF installation instructions

With ANRIN drainage systems, accumulating rainwater should be drained safely and quickly. Moreover, the structural elements have the task of accommodating dynamic loads arising from traffic-related demands and dispersing them to the area of the foundation.

Amongst others, the following technical rules and regulations in their respective valid versions must be observed for the selection, design and installation of ANRIN drainage systems.


The following installation guidelines are schematic representations. These are provided as examples and are non-binding. The information provided here is based on our long-term experience in excavation and road construction as well as the state-of-the-art technology. Despite this, designers and planners are always obligated to check the products and the installation instructions for their appropriateness. The example details are simplified recommendations for execution.

Constructions are to be re-created on a project-specific basis.

Image 1 SELF LC-150, 090, 125, 200 Installation guide

1.

Excavate trench. Fill in and pre-compact base course. Apply concrete pad, 3 parts sand + 1 part cement + 1 part water, to base course.

Image 2 SELF LC-150, 090, 125, 200 Installation guide

2.

Connect pipe connections to the pipeline.

Image 3 SELF LC-150, 090, 125, 200 Installation guide

3.

Place channel elements and sump unit on the concrete pad. Align components so that they are level.

Image 4 SELF LC-150, 090, 125, 200 Installation guide

4.

Position end caps.

Image 5 SELF LC-150, 090, 125, 200 Installation guide

5.

Complete the series and ensure the level alignment of the components.

Image 6 SELF LC-150, 090, 125, 200 Installation guide

6.

Backfill the concrete pad.

Image 7 SELF LC-150, 090, 125, 200 Installation guide

7.

Lay the paving.

Image 8 SELF LC-150, 090, 125, 200 Installation guide

8.

The surface should be 2 to 5 mm higher than the cover grating.

Instructions and Regulations

Guidelines and regulations
The current guidelines and regulations of the state-of-the-art technology must be observed for the installation.


For example, these are:
DIN EN 1433 „Drainage channels for vehicular and pedestrian areas
DIN 19580 „Drainage channels for vehicular and pedestrian areas
RStO „Guidelines for the standardisation of the superstructure of vehicular areas
DIN EN 206-1 „Concrete. Specification, performance, production and conformity
DIN EN 1045-2 „Concrete, reinforced and prestressed concrete structures. Part 2: Concrete – Specification, properties,
production and conformity; Application rules for DIN EN 206-1